ASF hydrophore units
An ASF water system unit with a self-priming injector pump and a tank with a rubber sack, of 20 L or 60 L capacity. The rubber sack in the tank separates water delivered into it from the gas cushion. This solution prevents water contact with the hydrophore tank, thus prolonging its life by eliminating corrosion. The unit is provided with CAM pumps powered by single-phase motors of 220 – 240 V voltage.
Application
- for garden watering with subsurface waters or from open tanks.
Photo gallery
Construction and installation dimensions
Technical parameters
Item |
Product marking |
Tank |
Agregat |
Utility water volume |
Motor switch (setting range or switching current) [A] |
LCA.2 connector setting |
|||||
VC [l] |
Weight |
Pump type |
Capacity Q [m3/h] |
Power [kW] |
Voltage |
Weight [kg] |
|||||
1. |
ASF.2.14.1 |
20 |
6,5 |
PXC800 |
2,8 ÷ 0,7 |
0,70 |
230 |
12,0 |
6,0 |
6 |
0,12÷0,27 |
2. |
ASF.2.14.1 |
20 |
6,5 |
CAM 80 |
2,7 ÷ 0,6 |
0,80 |
230 |
12.5 |
6,0 |
6 |
0,12÷0,27 |
3. |
ASF.3.15.1 |
60 |
15 |
CAM 80 |
4,38 ÷ 0,6 |
0,90 |
230 |
28,0 |
15,3 |
6 |
0,18÷0,30 |
Item |
Product marking |
L |
B |
H |
C |
D |
DN |
1. |
ASF.2.14.1 |
560 |
270 |
580 |
298 |
218 |
1" |
2. |
ASF.3.15.1 |
770 |
360 |
750 |
295 |
290 |
1¼" |
Voltage marking
1 – 230 V voltage
Construction designs
Construction designs are marked with the code e e1e1e2 , where:
e = 0 – without a valve
e1e1 = 35 – with a horizontal tank with a rubber sack, painted inside
e2=0 – reserve
Delivery scope
1 – self-priming pump – monoblock with a motor
2- hydrophore tank with a rubber sack
3 – pressurised connector MP5
4 – manometer
5 – pump-tank connection (flexible hose in metal braid)
Water system unit marking
ASF – unit type
2 – tank size type
14 – marking of the connector set
1 – voltage marking
0350 – design