HVP hydrophore tanks
A pressure HVP tank is made of low-carbon steel sheets, fully welded, of capacities 100, 150, 200, 300, 500, 1000 and 1500 litres. The water units with a hydrophore tank can be connected only to a non-pressure water intake. The tank can be installed only in the systems, in which max. pressure does not exceed the design pressure of a given tank type. Inside it is covered with a protective zinc coating.
The tank is supported in a vertical position by 3 legs welded on the tank circumference. In the cylinder part, elbow joints contain a water-gauge tube showing a water level in the tank. A cleaning hole is in the tank jacket. In the upper part of the tank there is a G2 hole, stopped with a threaded hob with a manometer installed.
Pressure tanks are designated for:
• supplying water to residential and farm buildings from:
- own water intake
- shallow water-bearing layers from timbered wells
- drilled
- ponds
- reservoirs
- hydrophore sets as a water and air tank
• allotments
• summer houses
• fountain supply.
Tanks are hot-dip galvanised
Photo gallery:
Design and technical parameters:
- HVP100, 200, 300, 500 tanks
Item |
Drawing |
Cap. |
Dz |
H |
h |
H1 |
H2 |
H3 |
H4 |
Gp mm |
Gd mm |
Design pressure MPa |
Initial pressure MPa |
Design temp. |
Weight |
1. |
HVP100 |
0,1 |
500 |
767 |
400 |
545 |
270 |
360 |
360 |
2,5 |
3,0 |
0,9 |
1,29 |
20 |
40 |
2. |
HVP200 |
0,2 |
550 |
1066 |
712 |
780 |
320 |
360 |
360 |
2,5 |
3,0 |
0,9 |
1,29 |
20 |
50 |
3. |
HVP300 |
0,3 |
550 |
1354 |
1000 |
920 |
320 |
360 |
360 |
2,5 |
3,0 |
0,9 |
1,29 |
20 |
60 |
4. |
HVP500 |
0,5 |
750 |
1387 |
1000 |
970 |
370 |
425 |
425 |
2,5 |
3,0 |
0,6 |
0,86 |
20 |
115 |
- HVP101, 151, 202, 201, 301 tanks
Item |
Drawing |
Poj. |
Dz |
H |
h |
H1 |
H2 |
H3 |
H4 |
Gp mm |
Gd mm |
Ciśn. obl. MPa |
Ciśn. prób. MPa |
Temp. |
Masa |
1. |
HVP101 |
0,1 |
500 |
767 |
400 |
470 |
270 |
360 |
270 |
2,2 |
2,5 |
0,6 |
0,86 |
20 |
39 |
2. |
HVP151 |
0,15 |
500 |
967 |
600 |
570 |
270 |
360 |
270 |
2,2 |
2,5 |
0,6 |
0,86 |
20 |
45 |
3. |
HVP202 |
0,2 |
500 |
1217 |
850 |
670 |
270 |
360 |
270 |
2,2 |
2,5 |
0,5 |
0,72 |
20 |
48 |
4. |
HVP201 |
0,2 |
550 |
1066 |
712 |
780 |
370 |
360 |
270 |
2,2 |
2,5 |
0,6 |
0,86 |
20 |
48 |
5. |
HVP301 |
0,3 |
550 |
1354 |
1000 |
920 |
320 |
360 |
270 |
2,2 |
2,5 |
0,6 |
0,86 |
20 |
57 |
- HVP1001 tanks
Drawing |
Cap. |
Dz |
H |
h1 |
h2 |
h3 |
h4 |
Gp mm |
Gd mm |
Design pressure MPa |
Initial pressure MPa |
Design temp. |
Weight |
HVP1001 |
1,0 |
908 |
1952 |
1200 |
578 |
600 |
638 |
4 |
4 |
0,8 |
1,14 |
20 |
208 |
- HVP1500 tanks
Drawing |
Cap. |
Dz |
H |
h1 |
h2 |
h3 |
Gp mm |
Gd mm |
Design pressure bar |
Initial pressure bar |
Design temp. |
Weight |
HVP1500 |
1,5 |
1010 |
2332 |
1500 |
800 |
700 |
5 |
5 |
10 |
14,3 |
20 |
340 |